Philip Søeberg <philip@soeberg.net>: Author Summary
Build | Completed | Code commits | Tests |
---|---|---|---|
OZW › OZWMAC › #479 | 4 years ago | Testless build | |
OZW › OZWMAC › #484 | 4 years ago |
Updated ZHC5010 configuration
I have four of these nodes working through v1.4 and v1.5 for node-red and domoticz and phyton. To assist first-time users with these units, it is important that: 1) ZHC5010 Configuration which can enable/disable direct control over relay can be controlled and 2) ZHC5010 responds fast by default. To do this, XML config file must have 1) MultiInstance CC set to mapping="all" (Yes, redundant but description enables users to change if instance0 is not needed (No direct Relay control) 2) Disable CC SWITCH_ALL. It seem not supported in v2.03 firmware (and earlier) and it cause OZW to timeout on startup. 3) Remove default Controller associations to any other CC than BASIC_REPORT, which is needed by Domoticz/Node-Red to learn of button-pres (which on/offs the internal switch). If Controller is associating with all possible association groups, RTT may go as high as 4500ms if quick-pressing different buttons on the ZHC5010. I suspect this is due to OZW polling the switch value after a BASIC_REPORT CC which seem to clog up ZHC5010s tx pipe, but thats guesswork. This XML configuration makes ZHC5010 respond quick and fast out-of-the-box (on new network joins.. for already joined devices you still need to manually change associations or leave/join again). Also updated some descriptions |
Testless build |
OZW › OZWLNX › #902 | 4 years ago |
Updated ZHC5010 configuration
I have four of these nodes working through v1.4 and v1.5 for node-red and domoticz and phyton. To assist first-time users with these units, it is important that: 1) ZHC5010 Configuration which can enable/disable direct control over relay can be controlled and 2) ZHC5010 responds fast by default. To do this, XML config file must have 1) MultiInstance CC set to mapping="all" (Yes, redundant but description enables users to change if instance0 is not needed (No direct Relay control) 2) Disable CC SWITCH_ALL. It seem not supported in v2.03 firmware (and earlier) and it cause OZW to timeout on startup. 3) Remove default Controller associations to any other CC than BASIC_REPORT, which is needed by Domoticz/Node-Red to learn of button-pres (which on/offs the internal switch). If Controller is associating with all possible association groups, RTT may go as high as 4500ms if quick-pressing different buttons on the ZHC5010. I suspect this is due to OZW polling the switch value after a BASIC_REPORT CC which seem to clog up ZHC5010s tx pipe, but thats guesswork. This XML configuration makes ZHC5010 respond quick and fast out-of-the-box (on new network joins.. for already joined devices you still need to manually change associations or leave/join again). Also updated some descriptions |
479 passed |
OZW › ODB › #20 | 4 years ago |
Updated LogicSoft ZHC5010 config file for v2.03 firmware.
- v2.03 includes new configuration directives and also support S0 secure inclusion mode - Improved on all configuration directives text - Added MULTI CHANNEL ASSOCIATION CLASS support. - OpenZWave users (Domoticz, etc.) now out-of-box can use all four buttons |
478 passed |
OZW › OZWLNX › #874 | 4 years ago |
Updated LogicSoft ZHC5010 config file for v2.03 firmware.
- v2.03 includes new configuration directives and also support S0 secure inclusion mode - Improved on all configuration directives text - Added MULTI CHANNEL ASSOCIATION CLASS support. - OpenZWave users (Domoticz, etc.) now out-of-box can use all four buttons |
1 of 465 failed |
Build | Completed | Code commits | Tests |
---|---|---|---|
OZW › OZWLNX › #874 | 4 years ago |
Updated LogicSoft ZHC5010 config file for v2.03 firmware.
- v2.03 includes new configuration directives and also support S0 secure inclusion mode - Improved on all configuration directives text - Added MULTI CHANNEL ASSOCIATION CLASS support. - OpenZWave users (Domoticz, etc.) now out-of-box can use all four buttons |
1 of 465 failed |
Build | Completed | Code commits | Tests |
---|
- v2.03 includes new configuration directives and also support S0 secure inclusion mode
- Improved on all configuration directives text
- Added MULTI CHANNEL ASSOCIATION CLASS support.
- OpenZWave users (Domoticz, etc.) now out-of-box can use all four buttons